Pneumatic Single Acting Actuator Valve

STAINLESS STEEL 304 3PC BALL VALVE SCREW END WITH SINGLE ACTING ACTUATOR

The STAINLESS STEEL 304 3PC BALL VALVE SCREW END WITH SINGLE ACTING ACTUATOR is a pneumatically actuated ball valve with spring-return single-acting cylinder for fail-safe operation. The 3-piece stainless steel body with screw ends provides tight sealing and reliable performance in corrosive applications.

Contact Sales

Product Overview

This pneumatically actuated valve provides dependable valve automation with spring-return single-acting cylinder for fail-safe operation. Suitable for industrial process control requiring safety and reliability.

Product Features

  • Single-acting spring-return actuator for fail-safe operation
  • Automatically returns to safe position on air failure
  • ISO 5211 direct mounting interface
  • Visual valve position indicator
  • Adjustable spring tension for proper torque

Technical Specifications (For reference only. The actual parameters need to be verified with us).

ParameterValue / Unit
Product TypeQuarter-turn Electric Actuator (On/Off)
Model / SeriesGVA000 (GVA003~GVA200)
Torque Range50~1000 Nm
Ambient Temperature-25°C ~ +60°C
Stem MaterialAlloy steel shaft/adaptor
ConnectionISO 5211 mounting flange
Actuation / OperationElectric motor (on/off), manual handwheel override
Applicable StandardsISO 5211
Design StandardISO 5211 mounting
Mounting StandardISO 5211 mounting flange
CertificationCE, ISO 9001
Protection ClassIP67, NEMA 4/6
Housing MaterialAluminum alloy housing
Output Angle90°±1° (270° optional)
Power Supply110-120V / 220-240VAC (380V, AC/DC24V optional)

FAQ

What is the fail-safe position?

Single-acting actuators use spring return to either fail-open or fail-close position, depending on installation orientation and application requirements.

What air supply pressure is required?

Standard 3-8 bar; must exceed spring return pressure plus valve torque requirement; consult factory for sizing.

Can the fail-safe direction be changed?

Yes, by reversing the actuator mounting or using a different model; consult factory for specific configuration.

How does it differ from double-acting?

Single-acting uses air for one stroke and spring for the other (fail-safe); double-acting uses air for both strokes and holds position on air loss.

What maintenance is required?

Regular inspection of air supply, filter regulator, and spring condition; springs are designed for long service life under normal operating conditions.