Skip to content

Pneumatic Single Acting Actuator Valve

CAST IRON BODY STAINLESS STEEL DISC NBR SEAT WAFER BUTTERFLY VALVE SINGLE ACTING

The CAST IRON BODY STAINLESS STEEL DISC NBR SEAT WAFER BUTTERFLY VALVE SINGLE ACTING is a resilient-seated butterfly valve for on/off and throttling service with low torque operation.

Contact Sales

Product Overview

This pneumatically actuated valve provides dependable valve automation with spring-return single-acting cylinder for fail-safe operation. Suitable for industrial process control requiring safety and reliability.

Product Features

  • Single-acting spring-return actuator for fail-safe operation
  • Automatically returns to safe position on air failure
  • ISO 5211 direct mounting interface
  • Visual valve position indicator
  • Adjustable spring tension for proper torque

Technical Specifications (For reference only. The actual parameters need to be verified with us).

ParameterValue / Unit
Product TypeWafer Butterfly Valve
Model / SeriesGBF2000 series
Size / DiameterDN40 - DN300 (1-1/2" - 12")
Pressure RatingPN16
Process TemperatureNBR seat: -10°C ~ +80°C
Body MaterialCast Iron / Ductile Iron GGG40
Disc MaterialStainless Steel SS316 / Ductile iron Nylon
Stem MaterialStainless Steel SS416
Seat MaterialNBR
ConnectionWafer lug type, ISO 5211
ActuationPneumatic single acting (spring return)
Applicable MediumHot/cold water, oil, gas & air
Applicable StandardDesign BS EN 593 / API 609; actuator ISO 5211 & NAMUR, 6 bar air
Design StandardDesign: BS EN 593 / API 609
Face-to-Face StandardFace-to-face: BS EN 558-1 / API 609
Flange StandardFlange: EN 1092-1 PN10/16, JIS B2210 10K
Testing StandardBS EN 12266-1 / API 598
CertificationActuator ISO 5211 / NAMUR

FAQ

What is the fail-safe position?

Single-acting actuators use spring return to either fail-open or fail-close position, depending on installation orientation and application requirements.

What air supply pressure is required?

Standard 3-8 bar; must exceed spring return pressure plus valve torque requirement; consult factory for sizing.

Can the fail-safe direction be changed?

Yes, by reversing the actuator mounting or using a different model; consult factory for specific configuration.

How does it differ from double-acting?

Single-acting uses air for one stroke and spring for the other (fail-safe); double-acting uses air for both strokes and holds position on air loss.

What maintenance is required?

Regular inspection of air supply, filter regulator, and spring condition; springs are designed for long service life under normal operating conditions.