Pneumatic Single Acting Actuator Valve
CAST IRON BODY STAINLESS STEEL DISC NBR SEAT WAFER BUTTERFLY VALVE SINGLE ACTING
The CAST IRON BODY STAINLESS STEEL DISC NBR SEAT WAFER BUTTERFLY VALVE SINGLE ACTING is a resilient-seated butterfly valve for on/off and throttling service with low torque operation.
Product Overview
This pneumatically actuated valve provides dependable valve automation with spring-return single-acting cylinder for fail-safe operation. Suitable for industrial process control requiring safety and reliability.
Product Features
- Single-acting spring-return actuator for fail-safe operation
- Automatically returns to safe position on air failure
- ISO 5211 direct mounting interface
- Visual valve position indicator
- Adjustable spring tension for proper torque
Technical Specifications (For reference only. The actual parameters need to be verified with us).
| Parameter | Value / Unit |
|---|---|
| Product Type | Wafer Butterfly Valve |
| Model / Series | GBF2000 series |
| Size / Diameter | DN40 - DN300 (1-1/2" - 12") |
| Pressure Rating | PN16 |
| Process Temperature | NBR seat: -10°C ~ +80°C |
| Body Material | Cast Iron / Ductile Iron GGG40 |
| Disc Material | Stainless Steel SS316 / Ductile iron Nylon |
| Stem Material | Stainless Steel SS416 |
| Seat Material | NBR |
| Connection | Wafer lug type, ISO 5211 |
| Actuation | Pneumatic single acting (spring return) |
| Applicable Medium | Hot/cold water, oil, gas & air |
| Applicable Standard | Design BS EN 593 / API 609; actuator ISO 5211 & NAMUR, 6 bar air |
| Design Standard | Design: BS EN 593 / API 609 |
| Face-to-Face Standard | Face-to-face: BS EN 558-1 / API 609 |
| Flange Standard | Flange: EN 1092-1 PN10/16, JIS B2210 10K |
| Testing Standard | BS EN 12266-1 / API 598 |
| Certification | Actuator ISO 5211 / NAMUR |
FAQ
What is the fail-safe position?
Single-acting actuators use spring return to either fail-open or fail-close position, depending on installation orientation and application requirements.
What air supply pressure is required?
Standard 3-8 bar; must exceed spring return pressure plus valve torque requirement; consult factory for sizing.
Can the fail-safe direction be changed?
Yes, by reversing the actuator mounting or using a different model; consult factory for specific configuration.
How does it differ from double-acting?
Single-acting uses air for one stroke and spring for the other (fail-safe); double-acting uses air for both strokes and holds position on air loss.
What maintenance is required?
Regular inspection of air supply, filter regulator, and spring condition; springs are designed for long service life under normal operating conditions.