Pneumatic Double Acting Actuator Valve
STAINLESS STEEL BODY STAINLESS STEEL DISC PTFE SEAT WAFER BUTTERFLY VALVE DOUBLE
The STAINLESS STEEL BODY STAINLESS STEEL DISC PTFE SEAT WAFER BUTTERFLY VALVE DOUBLE is a resilient-seated butterfly valve for on/off and throttling service with low torque operation.
Product Overview
This pneumatically actuated valve provides dependable valve automation with double-acting cylinder for fast, reliable operation. Suitable for industrial process control requiring quick response and consistent performance.
Product Features
- Double-acting pneumatic actuator for fast operation
- ISO 5211 direct mounting interface
- Visual valve position indicator
- Adjustable travel stops for precise positioning
- Suitable for on/off and modulating control
Technical Specifications (For reference only. The actual parameters need to be verified with us).
| Parameter | Value / Unit |
|---|---|
| Product Type | Wafer Butterfly Valve |
| Model / Series | GBF2000 series |
| Size / Diameter | DN40–DN300 |
| Pressure Rating | PN16 / ANSI 150# |
| Process Temperature | EPDM seat: -15 to +110°C |
| Body Material | Stainless Steel CF8M (SS316) |
| Disc Material | Stainless Steel SS316 / Ductile iron Nylon |
| Stem Material | Stainless Steel SS416 |
| Seat Material | PTFE reinforced |
| Connection | Wafer lug type, ISO 5211 |
| Actuation | Gearbox |
| Applicable Medium | Hot/cold water, oil, gas & air |
| Applicable Standard | Design BS EN 593 / API 609; test BS EN 12266-1 / API 598 |
| Design Standard | Design: BS EN 593 / API 609 |
| Face-to-Face Standard | Face-to-face: BS EN 558-1 / API 609 |
| Flange Standard | Flange: EN 1092-1 PN10/16 |
| Testing Standard | BS EN 12266-1 / API 598 |
| Certification | ISO 5211 mounting pad |
FAQ
What happens if air supply is lost?
Double-acting actuators hold their last position on air loss; for fail-safe operation, consider single-acting spring-return models or use air reservoir.
What air supply pressure is required?
Standard 3-8 bar (40-120 psi); verify torque requirements for your specific valve size and application.
Can it be used for modulating control?
Yes, with a 4-20mA positioner installed, the valve can provide precise flow modulation.
What is the typical cycle time?
Cycle time depends on valve size and actuator bore; typically 1-5 seconds for small to medium valves.
Are limit switches included?
Limit switch boxes are optional; standard actuators include a basic visual position indicator only.